To modify port mirroring settings:
1. Click . The Port Mirroring Settings Page opens.
Figure 129: Port Mirroring Settings Page
2. Modify the Type eld.
3. Click . Port mirroring settings are modified,
and the device is updated.
To remove port mirroring:
1. Click Maintenance > Diagnostics > Port Mirroring. The Port Mirroring Page opens.
2. Click the Remove checkbox for selected item, and click .
14.2 Viewing Integrated Cable Tests
The Copper Cable Page contains elds for performing tests on copper cables. Cable testing provides information about
where errors occurred in the cable, the last time a cable test was performed, and the type of cable error, which occurred. The
tests use Time Domain Reectometry (TDR) technology to test the quality and characteristics of a copper cable attached to a
port. Cables up to 120 meters long can be tested. Cables are tested when the ports are in the down state, with the exception
of the Approximated Cable Length test.
To view cable test results:
Click System > Maintenance > Diagnostics > Copper Cable. The Copper Cable Page opens:
Figure 130: Copper Cable Page
The Copper Cable Page contains the following elds:
Port Specifies the port to which the cable is
connected.
Test Result Displays the cable test results. Possible
values are:
No Cable Indicates that a cable is not connected
to the port.
Open Cable Indicates that a cable is connected
on only one side.
Short CableIndicates that a short has occurred in
the cable.
OK Indicates that the cable passed the test.
Cable Fault Distance Indicates the distance from the port where the cable error occurred.
Last Update Indicates the last time the port was tested.
Cable Length Indicates the approximate cable length. This test can only be performed when the port is up and
operating at 1 Gbps.
To perform a test:
1. Click . The test parameters are displayed in the Copper Cable Test Page: